1. Check if the air source has air
2. Is the pressure detected by the pressure solenoid valve adjusted high
3. Is there a disconnection in the connecting line
4. The air pressure solenoid valve is broken
When there is a lack of air pressure, first check the pressure gauge to see if it is really a lack of air pressure. If it is really a lack of air pressure or a lack of air, check the air source.
If there is gas and an alarm is triggered, you can check if the pressure solenoid valve has set the pressure too high. Generally, it is enough to set it to 4MPA, but if it is too high, it can be reduced to 4MPA.
If the air pressure solenoid valve is not set too high, you can short circuit the signals X21 and+24V connected to the air pressure solenoid valve to see the diagnostic input signal in the system (FANUC system is the "signal" X3.0 in "PMC maintenance").
The new generation system is equipped with a diagnostic signal I016. Is there a signal change? If there is a signal change, it may be a problem with the air pressure solenoid valve. You can try replacing it with a new one.
·How should we improve the quality of precision parts processing? ·CNC measurement machine function introduction ·How to solve the cracks in metal die castings? ·What are the milling methods of Longmen Machining Center? ·Weld ·CNC measuring machine ·How to eliminate the stress problem of metal die casting die? ·The processing of high precision parts can also be carried out according to the CNC processing manuf ·The main role of the connector contact plating using the electroplating process ·Future Development of Metal Die Casting